Uniks current clamp is designed for use in both industrial and civil applications. It makes TRMS measurements of Voltage up to 600V AC/DC and Current from 10mA up to 600A AC.


 

Uniks C6 performs the following measurements:

  • DC/AC TRMS Voltage up to 600V
  • AC Current TRMS up to 600A
  • Minimum current value 10mA
  • InRush Current
  • Voltage measurement with low impedance VLoz
  • LPF Filter
  • Resistance and Continuity test with buzzer
  • Capacitance and Frequency
  • Duty cycle
  • Diode test
  • Temperature

The calibration certificate is not included in the package.

Do you have questions about this product or did you not find what you were looking for? Ask us!
Uniks Current Clamp 600V AC/DC C6
€83.13
€83.13

€83.13
Tax included

€83.13

Buy it within and receive it from Monday, 25 August
Two-year warranty
Easy return within 14 days

Package contents:

  • UNI97: 2 R and N 4mm CAT III 1000V/10A Ferrules
  • UNI300: Wire probe
  • UNIAD2: Adapter for K probe
  • UNI3300: Canvas carrying bag
  • User's manual
  • 3x 1.5V AAA batteries


     

Product benefits:

  • C6 Current Clamp allows you to illuminate the darkest areas thanks to a built-in LED Light
  • Uniks C6 current clamp allows you to measure the starting currents of motors using the InRush function
  • The inrush value will be calculated over 100ms and could be as much as 8/10 times the value at steady state current
  • In addition, the VloZ function will allow you to measure Voltage with low input impedance so you can check whether the measured voltage is a GHOST VOLTAGE or a real voltage
  • GHOST VOLTAGE Voltage is nothing more than the capacitive coupling between the line in question and another line. The line in question being upstream disconnected and being placed close to the other live line the latter through coupling could induce a voltage on the line and because of the high impedance of our multimeter we would risk reading it
  • The VloZ position therefore low impedance would charge the disconnected line bringing it to 0V potential as it really should be

     

Functions:

  • Points Display 6000
  • TRMS
  • Overload protections up to 600V TRMS
  • LPF Fitro
  • Auto Power Off
  • Low battery indicator
  • Backlighting
  • Integrated flashlight
  • Diode Test
  • Duty Cycle
  • Data Hold
  • MAX/MIN
  • CAT III 1000V and CAT IV 600V

     

Technical Specifications Range:

  • DC Voltage 600V
  • AC Voltage 600V
  • AC Current 600A
  • Resistance 60M
  • Temperature -20°C 1000°C
  • Capacity 100mF
  • Frequency 10kHz

     

Specifications Accuracy:

  • DC voltage ± 0.5% 3d
  • AC voltage ± 2.5% +5d
  • AC current ± 2.5% +8d
  • Resistance ± 1.0% +3d
  • Temperature ± 2.0% +2d
  • Capacity ± 4% +3d
  • Frequency ± 0.5% +5d

     

Characteristics:

  • 6,000 Measurement Points
  • Input surge protection 600V AC/DC RMS
  • Bandwidth for TRMS measurements of 1KHz
  • AC/DC voltage up to 600V
  • AC Current up to 600A
  • Minimum measurable current value 10mA AC
  • Resistance up to 60M?
  • Capacitance up to 100mF
  • Continuity
  • Frequency and Hz%
  • Diode test
  • NCV (Non-Contact Voltage Detector)
  • VLoz (Low Impedance Voltage Measurement)
  • VFD filter in Voltage and Current
  • Temperature (Type K Probe)

Data sheet