Notifier interface module 1 input 1 output CMA11E-NI

Notifier
NOT CMA11E-NI

The Notifier CMA11E-NI interface module with 1 input and 1 output in the same enclosure is designed for NOTIFIER addressable panels, with integrated isolator, supervised or relay output, and compact dimensions for installation in flush-mounted boxes type 503.

  • 1 input + 1 output in the same device

  • Module power supply: 15 ÷ 30 VDC (taken from the loop) 

  • Input voltage for external load: 5 ÷ 32 VDC from auxiliary power supply

  • Relay contacts: 1 A @ 30 VDC with resistive load

  • Maximum cable section: 1.5 mm²

  • Humidity: 10 ÷ 93% without condensation

  • Operating temperature: -10 °C ÷ +55 °C

  • Protection degree: IP30

  • Dimensions: 82 × 50 × 23 mm

  • Installation: flush-mounted boxes type B503

Do you have questions about this product or did you not find what you were looking for? Ask us!
Notifier interface module 1 input 1 output CMA11E-NI
€67.81
€67.81

€67.81
Tax included
Calculate shipping cost

Out of stock
Incoming
€67.81

Two-year warranty
Easy return within 14 days

Notifier Interface Module CMA11E-NI: 1 input and 1 output for addressable fire control panels

The Notifier CMA11E-NI is an addressable interface module that integrates 1 input and 1 output in the same enclosure, offering a compact and versatile solution for NOTIFIER fire detection systems. It is compatible with all the brand's addressable control panels, both with CLIP protocol and Advanced protocol, and represents a practical choice for managing technical signals and commands to external devices.

Thanks to microprocessor management, the integrated isolator, and its small size, the module is designed for professional installations where reliability, flexibility, and simplicity of wiring are required. Its compact structure allows it to be housed in B503 type flush-mounted boxes, facilitating integration into new or existing systems.

1 input and 1 output in the same module: compact and versatile solution

The strength of the CMA11E-NI is the combined presence of an input section and an output section in the same device. This configuration allows for optimization of space, wiring, and addressing, proving particularly useful when it is necessary to acquire a field signal and, at the same time, control an external device.

The input module can be used, for example, for reporting technical signals from fire protection devices or for acquiring alarms from non-addressable sensors. The output module, on the other hand, can be used to activate non-addressable optical-acoustic devices, electromagnets, shutter closures, or for resetting the power supply of conventional 24 Vdc detectors.

Compatible with CLIP and Advanced protocols

The module is compatible with all NOTIFIER addressable control panels that use CLIP protocol (1-99) or Advanced protocol (1-159), thus offering wide flexibility of use in fire systems of different generations.

In CLIP protocol, the module occupies two consecutive addresses on the loop: the first associated with the input and the second with the output. In Advanced protocol, however, it occupies a physical address with two consecutive software sub-addresses, one for the input and one for the output. Addressing is done via decimal rotary selectors, making configuration simple during installation.

Supervised output or potential-free relay

The output section of the CMA11E-NI can be configured in two main modes via dip-switch: CON = supervised output for polarized optical/acoustic indicators, and FORC = potential-free relay contact.

This dual possibility makes the module suitable for multiple applications. In the case of the supervised mode, a separate power supply is required for the connected optical-acoustic devices. In relay mode, however, the module can directly control external devices with clean contacts, expanding the possibilities of integration into the system.

Integrated isolator and status management via LED

The module incorporates an isolation device against short circuits, useful for increasing the reliability of the loop and limiting the effects of any faults on the line. When required by the application, the isolator can be excluded via a dedicated jumper.

The status of the device is easily monitored thanks to 2 tricolour LEDs, which indicate both communication with the control panel and the status of the input and output. A remote LED output is also available, useful for repeating the status indication in a different position from the module's installation point.

Loop-powered and high immunity to interference

The Notifier CMA11E-NI is powered directly from the 2-wire loop of the addressable control panel, with an operating voltage between 15 and 30 Vdc. This feature simplifies installation and reduces the need for additional wiring.

The module is designed to ensure high immunity to electromagnetic interference, an important feature in systems installed in technical or industrial environments. The contained absorption in various operating conditions also contributes to efficient management of loop resources.

Ideal applications in addressable fire systems

Thanks to the combination of input and output, compatibility with NOTIFIER protocols, and configuration flexibility, the CMA11E-NI is suitable for numerous applications in addressable fire systems.

It is ideal for reporting technical signals, il controllo di sirene e segnalatori ottico-acustici, la gestione di elettromagneti e serrande tagliafuoco, nonché per il reset di rivelatori convenzionali alimentati esternamente. Le dimensioni compatte lo rendono particolarmente utile quando serve installare il modulo in spazi ridotti.

Electrical specifications
Operating voltage 15 ÷ 30 VDC (taken from the loop).
Current consumption at rest 104µA (Isolator included, no communication)
Current consumption 172µA (Isolator included, communication with flashing LED)
Alarm consumption 1372µA (Isolator Included, 1 Red LED permanently on)
Alarm consumption with Output Activated 2572µA (Isolator Included, 2 Red LEDs permanently on)
Isolator Maximum impedance in the absence of shorts on the line with isolator inserted: Max110 mΩ
Input voltage for external load 5 ÷ 32 VDC (taken from auxiliary power supply)
Relay contacts 1 A 30 VDC with resistive load
Maximum connection cable section 1.5 mm²
Environmental specifications
Humidity 10 ÷ 93% (without condensation)
Operating temperature -10° ÷ +55°C
Protection degree IP30
Mechanical specifications
Dimensions 82x50x23mm
Weight 63 grams
Certifications
Performance certification 1293 – CPR – 0939
Conformity certification EMC/LVD 00032/101/1/2025