Telemecanique Contactor TeSys D 4P 40A AC1 220VAC LC1DT40M7
SNR LC1DT40M7
3389110577709
Schneider TeSys D Telemecanique contactor, with the following characteristics:
- Rated use voltage [Ue]: <= 690V "AC" 25...400 Hz Power circuit: <= 300V DC Power circuit.
- Rated use current [Ie]: 40 A 60 °C) "AC" AC-1 for Power circuit at <= 440V
- Control circuit type: AC at "50/60 Hz"
- Control voltage [Uc]: 220V "AC" "50/60 Hz"
- Number of poles: 4
- Power pole contact composition: 4 NO
- Auxiliary contact composition: 1 NO + 1 NC
- Rated impulse withstand voltage [Uimp]: 6 kV complying with IEC 60947
- Overvoltage category: Acti9 VigiARC iC40
- Conventional open air thermal current [Ith]: 10A at <60 °C for signaling circuit, 40A at <60 °C for power circuit
€78.80
€78.80
Items Available: 5
€78.80
Buy it within and receive it from Wednesday, 24 December
Other Specifications:
- Rated interrupting capacity: 450A at 440 V per Power Circuit in accordance with IEC 60947
- Average impedance: 2 mOhm "50 Hz" - Ith 40 A per Power Circuit
- Electrical endurance: 1.4 Mccycles 40 A AC-1 at Ue <= 440V
- Power dissipation per pole: 3.2 W AC-1
- Operation time: 4...19 ms opening, 12...22 ms closing
- Safety Reliability Level: B10d = 1369863 cycles Contactor with rated load in accordance with EN/ISO 13849-1, B10d = 20000000 cycles Contactor with mechanical load in accordance with EN/ISO 13849-1
- Mechanical life span: 15 Mccycles
- Maximum operating speed: 3600 cycles/h at <60 °C
- Coil technology: without integrated suppressor module
- VA inrush power: 70 VA 60 Hz 0.75 20 °C), 70 VA "50 Hz" 0.75 20 °C)
- VA holding power consumption: 7.5 VA 60 Hz 0.3 20 °C), 7 VA "50 Hz" 0.3 20 °C)
- Heat dissipation: 2 to 3 W at "50/60 Hz"
- Auxiliary contact type: Mechanically linked type 1 NO + 1 NC complying with IEC 60947-5-1, mirror contact type 1 NC complying with IEC 60947-4-1
- Signaling circ. frequency: 25...400 Hz
- Minimum switching current: 5 mA per signaling circuit
- Minimum switching voltage: 17V per signaling circuit
- No-overlap time: 1.5 ms upon deactivation between NC and NO contact, 1.5 ms upon activation between NC and NO contact
- Insulation resistance: > 10 MOhm per signaling circuit
- IP degree of protection: IP20 Front side complies with IEC 60529
- Climatic sealing: Conforms to IACS E10, complies with IEC 60947-1 Annex Q category D
- Protection treatment: TH complying with IEC 60068-2-30
- Pollution degree: 3
- Operating ambient temperature: -40/+60 °C - 60/+70 °C with derating
- Storage temperature: -60/+80 °C
- Operating altitude: 0 to 3000 m
- Fire resistance: 850 °C in accordance with IEC 60695-2-1
- Height 91 mm
- Width 45 mm
- Depth 99 mm
- Weight: 0.425 kg
Mechanical robustness:
- Open contactor vibration: 2 Gn, 5...300 Hz
- Closed contactor vibrations: 4 Gn, 5...300 Hz
- Closed contactor shocks: 15 Gn for 11 ms
- Contactor shocks open: 8 Gn for 11 ms
Control circuit voltage limits:
- 0.3...0.6 Uc -40...70 °C "AC" de-energizing 50/60 Hz
- 0.8...1.1 Uc -40...60 °C operating "AC" 50 Hz
- 0.85...1.1 Uc -40...60 °C operating "AC" 60 Hz
- 1...1.1 Uc 60...70 °C operating "AC" 50/60 Hz
Connections-clamps:
- Control circuit: screw clamp terminals 2 cables 1...2.5 mm²flexible with cable termination
- Control circuit: screw clamp terminals 1 wire 1...4 mm²flexible without cable termination
- Control circuit: screw terminals 2 cables 1...4 mm²flexible without cable termination
- Control circuit: screw terminals 1 wire 1...4 mm²flexible with cable termination
- Control circuit: screw terminals 1 cables 1...4 mm²solid without cable termination
- Control circuit: screw terminals 2 cables 1...4 mm²solid without cable termination
- Power circuit: connector 1 cable 2.5...10 mm²flexible without cable termination
- Power circuit: connector 2 cables 2.5...10 mm²flexible without cable termination
- Power circuit: connector 1 cable 2.5...10 mm²flexible with cable termination
- Power circuit: connector 2 cables 2.5...10 mm²flexible with cable termination
- Power circuit: connector 1 cable 2.5...16 mm²solid without cable termination
- Power circuit: connector 2 cables 2.5...16 mm²solid without cable termination
Tightening torque:
- Control circuit: 1.7 Nm - on EverLink connectors for BTR screws - with Ø 6 mm flat screwdriver
- Control circuit: 1.7 Nm - on EverLink connectors for BTR screws - with Philips screwdriver No 2
- Power circuit: 1.7 Nm - on EverLink connectors for BTR screws - with Ø 6 mm flat screwdriver
- Power circuit: 1.7 Nm - on EverLink connectors for BTR screws - with Philips screwdriver No 2
- Control circuit: 1.7 Nm - on EverLink connectors for BTR screws - with pozidriv screwdriver No 2
- Power circuit: 2.5 Nm - on EverLink connectors for BTR screws - with pozidriv screwdriver No 2
- On EverLink connectors for BTR screws
Rated insulation voltage [Ui]:
- 600 V CSA certified Power circuit:
- 600 V UL certified Power circuit:
- 690 V complying with IEC 60947-1 signaling circuit
- 600 V CSA certified signaling circuit:
- 600 V UL certified Signaling circuit:
- 690 V complying with IEC 60947-4-1 Power circuit.
Rated allowable short-time withstand current [Icw]:
- 50 A at <40 °C - 10 min per Power Circuit
- 120 A at <40 °C - 1 min per Power Circuit
- 240 A at <40 °C - 10 s per Power Circuit
- 380 A at <40 °C - 1 s per Power circuit
- 100 A - 1 s per signaling circuit
- 120 A - 500 ms per signaling circuit
- 140 A - 100 ms per signaling circuit
Associated fuse gauge:
- 10 A gG per signaling circuit in accordance with IEC 60947-5-1
- 63 A gG at <= 690 V coordination Type 1 for Power circuit
- 40 A gG at <= 690 V coordination Type 2 for Power circuit
Rated closing power Irms:
- 140A "AC" for signaling circuit complying with IEC 60947-5-1
- 250A DC for signaling circuit complying with IEC 60947-5-1
- 450A at 440 V for Power circuit complying with IEC 60947
Data sheet
- Type: Contactors
- Voltage: 220VAC
- Poles: 4P
- Degree of protection: IP20
- Amps: 40A