4Power Uninterruptible Power Supply UPS Third Power Plus 6000 6KVA THPPMM600010T
The UPS 4Power Third Power Plus 6000 (THPPMM600010T) 6kVA/6kW On-Line double conversion with PFC and inverter cos 1 ensures total continuity, pure sine wave, and advanced management for IT, LAN, and critical loads.
-
6000VA / 6000W with inverter at cos = 1 (100% usable power)
-
On-Line double conversion technology VFI-SS-II2: zero intervention time
-
Input PFC with IGBT rectifier (input cos 0.99)
-
VRLA AGM batteries (192/240 Vdc, 7Ah) with 68 h recharge
-
Typical autonomy 10/15 (80%/50% load), expandable up to 3 hours with external battery packs
-
Control and connectivity: LCD, RS232/USB, SNMP slot, automatic bypass and manual bypass provision.
UPS 4Power Third Power Plus: network isolation and advanced protection
The UPS 4Power Third Power Plus 6000 THPPMM600010T is designed to ensure continuous power and superior electrical quality in professional environments. Thanks to the On-Line double conversion technology, the load is always powered by the inverter: this eliminates micro interruptions and disturbances, providing regenerated, filtered, and stabilized voltage. The result is concrete protection for sensitive equipment, with zero intervention time in case of blackout and true isolation from network problems (spikes, overvoltages, undervoltages, and fluctuations).
Power 6kVA/6kW with cos 1: fully usable power
With inverter at cos = 1, the nominal power coincides with the active power: 6000VA = 6000W. This is an important advantage with modern loads (servers, storage, network devices, industrial electronics) because you can use the entire capacity of the UPS without penalties due to the power factor. It is a solid choice for rack cabinets, data centers, medical environments, and light industrial users where continuity and stability are fundamental.
PFC and IGBT rectifier: efficient absorption and cleaner network
The input stage with IGBT rectifier and PFC is designed to reduce the harmonic content (THDi) reset in the network and to phase the UPS at the input, bringing the cos to values of 0.99. In practice, the UPS works more efficiently, limits the impact on the electrical system, and helps to contain consumption and dissipation, especially in systems with many electronic users.
VRLA AGM batteries and expandable autonomy: tailored continuity
The UPS uses VRLA AGM batteries with voltage 192/240 Vdc and capacity 7Ah, with a recharge time of 6-8 hours. The declared autonomy is 10 minutes at 80% load and 15 minutes at 50% load, ideal for covering short blackouts or allowing controlled shutdown of systems. If longer times are needed, it is possible to add external battery packs and reach up to 3 hours of autonomy (depending on load and configuration), useful for sites with unstable networks or to ensure prolonged operational continuity.
Professional functions and monitoring: ABM, Hot Swap, EPO, SNMP
The Third Power Plus 6000 integrates a complete set of functions for reliability and maintenance: Cold Start, ABM (Automatic Battery Management), EPO (emergency shutdown), ACB warning for battery replacement, battery test, hot swap, auto restart, and automatic bypass with provision for external manual bypass. For management, you find an interactive LCD display, RS232/USB ports, SNMP slot, and supervision/shutdown software included, ideal for integration into IT infrastructures.
| GENERAL DATA | |
|---|---|
| Model | THPP6000 |
| Product code | THPPMM600010T |
| Nominal power | 6000 VA |
| Active power | 6000 W |
| INPUT | |
| Input voltage | 208 V, 220 V, 230 V, 240 V (1Ph + N) selectable |
| Input voltage range | 110 ÷ 300 Vac |
| Nominal frequency | 40 ÷ 70 Hz (autosensing) |
| Accepted frequency variation | ±5 Hz |
| Input power factor | ≥ 0.99 with THD < 2% |
| OUTPUT | |
| Nominal voltage | 208 V, 220 V, 230 V, 240 V (1Ph + N) selectable |
| Voltage stability | ±1% |
| Nominal frequency | 50 / 60 Hz ±0.1% (battery mode) |
| Waveform | Sine wave |
| Harmonic distortion (THD) | ≤ 2% with linear load |
| Crest factor | 3:1 |
| AC/AC efficiency | > 95% |
| Intervention time | Zero – On-line double conversion |
| Overload (25 °C) | <150% Pn for 30 s / >150% Pn for 1 s |
| BATTERIES | |
| Battery type | VRLA AGM |
| Battery voltage | 192 / 240 Vdc |
| Capacity | 7 Ah |
| Recharge time | 6 ÷ 8 h |
| Autonomy (80% / 50% load) | 10 min / 15 min |
| GENERAL INFORMATION | |
| Dimensions (W × D × H) | 191 × 465 × 711 mm |
| Peso | 53.0 kg |
| Telephone / LAN protection | RJ45 filter (10BaseT) |
| Communication | RS232 / USB |
| Safety / EMC compliance | EMC Dir. 2004/108/E: EN 62040-2:2006, EN 61000-6-1-3:2007 LVD Dir. 2006/95/EC: EN 62040-1:2008, EN 62040-3:2002 |
| Marks | CE |
| Operating temperature | 0 ÷ 40 °C (relative humidity up to 90%) |
| Operating altitude | Up to 3500 m (<95% RH, non-condensing) |
Data sheet
- Type: Uninterruptible Power Supply UPS
- Rated Power: 6000VA
- Active Power: 6000W
- Endurance: 10 minutes
15 minutes
: 1