Legrand Single Phase Double Conversion UPS WHAD CAB 2500VA 310117

Legrand
LEG 310117 3414970646729

Legrand single-phase double conversion UPS for MV/LV transformer substations WHAD CAB 2500VA, 160 minutes at 100W autonomy with the following characteristics:

 

  • Voltage: QMT
  • Active power: 1750 watts
  • Rated power: 2500 VA
  • Degree of protection: IP21
  • Height: 460 mm
  • Width: 160 mm
  • Depth: 425 mm
  • Series: Whad CAB, QMT
  • Autonomy: 160 minutes at 100W
Do you have questions about this product or did you not find what you were looking for? Ask us!
Legrand Single Phase Double Conversion UPS WHAD CAB 2500VA 310117
€1,471.77
€1,471.77

€1,471.77
Tax included
Calculate shipping cost

€1,471.77

Buy it within and receive it from Thursday, 12 February
Two-year warranty
Easy return within 14 days

The Legrand Whad CAB model UPS is an uninterruptible power supply for protection in MV/LV transformer substations complying with CEI 0-16 standard, with high-frequency PWM technology, On Line Double Conversion type, through-neutral, Nominal Power 2500 VA, 1750 W, equipped with valve-regulated hermetic type storage batteries, contained inside the UPS in a special compartment or in one or more external cabinets, sized to ensure minimum autonomy.


 

The Whad CAB UPS is equipped with a CHARGE RESERVE that allows the batteries to maintain a reserve of power to ensure that the coil can always be reset and full cabin functionality restored. The UPS rectifier consists of a control and regulation circuit (PFC), which in addition to normal rectifier functions provides:

  • Automatically correct the load power factor to return it to a value >0.99 already with an applied output load of 20% of the rated load
  • Power the inverter without requiring energy from the batteries even at very low line voltage (operation with mains power supply for VIN values of 110 Vac at 50% of rated load)
  • Ensure total harmonic distortion of the input current THDIin < 3% without the addition of additional filters or components


     

The bypass circuit is designed and implemented in accordance with the following: Electromechanical switch - Microprocessor-controlled command and control logic that provides:

  • Automatically transfer the load directly to the primary grid without interrupting the power supply, upon the occurrence of the conditions of overload, overtemperature, out-of-tolerance DC voltage, and inverter anomaly
  • Automatically re-transfer the load from primary grid to inverter line, without power interruption, upon the restoration of normal load conditions
  • If the primary grid and inverter are not synchronized, the bypass will have to be disabled

     

In order to safeguard batteries from damage from deep discharge, the minimum allowable battery voltage threshold automatically varies according to the applied load (default setting), while allowing the user the option of selecting fixed voltage threshold management.

 

Diagnostic and shutdown software, when properly installed in a PC connected to the UPS, provides access to all operating data, makes adjustments and settings of special functions, and controls shutdown of Windows and Linux operating systems.

 

General Features:

  • Type of operation: On-line double conversion
  • UPS structure: Redundant with 1,250 VA power modules, contained in a single cabinet
  • Waveform in mains/battery operation: Sine / Sinusoidal
  • Switching time: Zero


     

Input characteristics:

  • Rated input voltage: 230 V
  • Input voltage range: 184 V to 264 V at rated load
  • Minimum mains operating voltage: 110 V at 50% load
  • Input frequency: 50 Hz or 60Hz (user selectable)
  • Power factor: > 0.99 from 80% to 100% of rated load
  • Inrush current: Maximum 100% of load current

     

Output characteristics (mains operation):

  • Rated output voltage: 230 V ± 1%
  • Rated/active output power: 2500 VA / 1750 W
  • Rated output frequency: 50 Hz or 60 Hz (user selectable)

     

Output characteristics (battery operation):

  • Rated output voltage: 230 V ± 1%
  • Output frequency: 50 Hz or 60 Hz ± 1%
  • Rated/active output power: 2500 VA / 1750 W

     

Battery characteristics:

  • Battery type: Lead-acid, sealed, maintenance-free
  • Autonomy: 160 minutes at 100W
  • Unit capacity: 9 Ah (12V)
  • Battery module protection: 2 fuses for each battery module

Data sheet

Type:
Uninterruptible Power Supply UPS
Rated Power:
2500VA
Active Power:
1750W
Endurance:
160 minutes
Contact details of the manufacturer and the responsible person