Schneider Residual Current operated Circuit Breaker 10A 1P+N 4.5kA 30mA AC Curve C 2M R9D60610

Schneider
SNR R9D60610 3606481928795

Schneider Residual Current operated Circuit Breaker, combined protection against short circuits, overloads and current leakage. Ideal for domestic and industrial installations, with the following characteristics:

  • Rated current: 10 amps

  • Number of poles: 1P+N

  • Operating voltage: 230V AC

  • Interrupting capacity: 4.5 kA

  • Differential current: 30 mA

  • Tripping curve: C

  • Differential type: AC

  • Number of modules: 2

  • Degree of protection: IP20

Do you have questions about this product or did you not find what you were looking for? Ask us!
Schneider Residual Current operated Circuit Breaker 10A 1P+N 4.5kA 30mA AC Curve C 2M R9D60610
€28.45
€28.45

€28.45
Tax included

€28.45

Buy it within and receive it from Tuesday, 12 August
Two-year warranty
Easy return within 14 days

Comprehensive protection for your electrical system

Schneider RCBO, integrates three basic protections:

  • Magnetic protection against short circuits, preventing fire and damage to the system
  • Thermal protection against overloads, preventing interruptions due to excessive loads
  • Differential protection (30mA) against current leakage, ensuring the safety of people

This combination makes it an essential device for electrical safety in homes, offices and small businesses.

Schneider RCBO: C curve and AC type protection

C curve: ideal protection for mixed loads

Thanks to the C-curve tripping curve, the device is suitable for circuits with mixed loads, such as outlets and lighting, reducing the risks of unwanted interruptions.

Operation of the AC-type RCBO

This device is of the AC type, so it is sensitive to sine-sine alternating differential currents, ensuring rapid tripping in both sudden losses and gradual increases, ensuring high safety standards.

Schneider RCBO: robustness, reliability and compliance

Robust and compact design

Designed for quick and easy DIN-rail installation, the device is 2 modules wide, taking up little space in the electrical panel. Constructed with halogen- and silicone-free materials, it provides enhanced environmental safety and durability.

Certified reliability and regulatory compliance

Made in accordance with CEI EN 61008-1 standards, it ensures safe and timely tripping of sine-sine alternating differential currents. It has a mechanical life of 10,000 switching cycles, ensuring reliable performance over time.

Features of the Schneider RCBO

Technical Data

Feature Value
Rated current 10A
Number of poles 1P+N
Voltage 230V AC
Differential current 30 mA
Breaking capacity 4.5 kA
Tripping curve C
Type of differential AC
Number of modules 2


Installation and Protection

Feature Value
Degree of protection IP20


Dimensions

Feature Value
Height 85mm
Width 36 mm
Depth 73 mm

Data sheet

Modules:
2
Poles:
1P+N
Curve:
C
Breaking capacity:
4.5KA
RCD Type:
AC
Differential current :
0.03A
Amps:
10A
Circuit Protections:
RCBO