BTICINO MY HOME - probe for fan-coil with speed selection HC4692FAN


BTI HC4692FAN 8012199823096

Axolute BTICINO MY HOME probe, to control the room temperature for heating and cooling systems. Equipped with knob for variation of ± 3 ° C from the temperature set in the central unit and for the selection of OFF and antifreeze modes with manual / automatic speed selection for fan-coil and Idrorelax system. Voltage 27 Vdc, current In 6 mA, 2 modules.

Request info about this product

BTICINO MY HOME - probe for fan-coil with speed selection HC4692FAN

€118.30 Tax included
€118.30

BTICINO MY HOME - probe for fan-coil with speed selection HC4692FAN

€118.30
Tax included
klarna Pay in installments with Klarna
Items Available: 1
qty

BTICINO MY HOME - probe for fan-coil with speed selection HC4692FAN

€118.30

Buy it within and receive it from Tuesday, 13 June
Two-year warranty
Secure Payment
Easy return within 14 days

The device allows to adjust the room temperature both in winter and in summer, allowing to change locally the settings from those received from the central unit. The article is equipped with a knob for the local selection of the temperature (limited to +/-3°C compared to the value set by the central unit), of the antifreeze mode and of the OFF mode. On the front of the article there are two leds, one green and one yellow. The green led indicates the correct functioning of the device and the activation of the antifreeze and OFF modes of the corresponding zone. The yellow led indicates the status of the actuators and any anomalies of the same.

OFF mode: This mode has the highest priority, whether it is selected by the probe or set by the control unit; to exit OFF mode it is necessary to operate from the same device from which it was set.

Antifreeze/thermal protection mode: In this position, if the thermoregulation system is set as heating, the probe works in antifreeze mode; if it is set as cooling, it works in thermal protection mode. The probe can also work in collaboration with other probes in "master" configuration to allow the central unit to calculate an average temperature on several detection points. The usefulness of this function is the management of very large environments, within which the temperature can vary significantly. In case of failure of the central unit, the probe continues to work with the last settings received, thus maintaining continuously the last temperature determined with summer or winter settings. The OFF mode, eventually selected on the probe, has anyway priority also in case of failure of the central unit, so the zone controlled by the probe will remain off. The probe allows to control a zone with a maximum of 9 actuators of the same type and 8 slave probes (4693, 573921, 573920 and 067458).

Configuration: This probe has been developed specifically for the management of 3-speed fan-coils and Climaveneta fan-coils, it has only three locations for configuration: ZA, ZB, SLA. The ZA and ZB housings must always be used for configuration operations by inserting two configurators that identify the address of the device, and therefore the number of the zone controlled by the probe itself. The actuators controlled by this probe must be configured with the same zone address.