Telemecanique Standard Control Unit LUCA 3-12A 24V AC LUCA12B


SNR LUCA12B 3389110363913

Schneider Telemecanique LUCA standard control box/control unit, with the following characteristics:

 

  • Rated operating voltage [Ue]: 690V "AC"
  • Mains frequency: 40...60 Hz
  • Type of load: three-phase motor - cooling: self-cooled
  • Motor rated current adjustment range: 3...12A
  • Trip threshold: 14.2 x Ir +/- 20 %
  • Phase failure sensitivity: yes
  • Control circuit voltage: 24V AC
  • Rated impulse withstand voltage [Uimp]: 6 kV in accordance with IEC 60947-6-2
Request info about this product

Telemecanique Standard Control Unit LUCA 3-12A 24V AC LUCA12B

€113.47
€113.47

Telemecanique Standard Control Unit LUCA 3-12A 24V AC LUCA12B

€113.47
Tax included
klarna Pay in installments with Klarna
qty

Telemecanique Standard Control Unit LUCA 3-12A 24V AC LUCA12B

€113.47

Buy it within and receive it from Thursday, 13 June
Two-year warranty
Secure Payment
Easy return within 14 days

Other technical features:

  • Mounting type: plug-in (front side)
  • Protection treatment: TH in accordance with IEC 60068
  • Operating ambient temperature: -25/+70 °C
  • Storage temperature: -40/+85 °C
  • Operating altitude: Acti9 iCV40 ARC
  • Immunity to radioelectric fields: 10V complying with IEC 61000-4-6
  • Immunity to microinterruptions: 3 ms
  • Immunity to voltage spikes: 70 % / 500 ms in accordance with IEC 61000-4-11

     

Motor power in kW:

 

  • 5.5 kW at 400...440 V "AC" "50/60 Hz"
  • 5.5 kW at 500 V "AC" "50/60 Hz"
  • 9 kW at 690 V "AC" "50/60 Hz"

     

 

Thermal overload trip class:

 

  • Class 10 complying with IEC 60947-6-2 - frequency limit: 40...60 Hz - temperature compensation: -25...70 °C
  • Class 10 in accordance with UL 508 - frequency limit: 40...60 Hz - temperature compensation: -25...70 °C

     

IP rating:

 

  • IP20 front panel and wired terminals complies with IEC 60947-1
  • IP20 other sides complies with IEC 60947-1
  • IP40 front panel outside connection area complies with IEC 60947-1

     


Fire resistance:

  • 960 °C parts supporting live components complies with IEC 60695-2-12
  • 650 °C complying with IEC 60695-2-12

     

 

Impact resistance:

 

  • 10 gn open power poles complies with IEC 60068-2-27
  • 15 gn power poles closed conforms to IEC 60068-2-27

     

 

Vibration resistance:

 

  • 2 gn 5...300 Hz open supply poles complies with IEC 60068-2-6
  • 4 gn 5...300 Hz supply poles closed conforms to IEC 60068-2-6

     

 

Electrostatic discharge resistance:

 

  • 8 kV level 3 in open air complies with IEC 61000-4-2
  • 8 kV level 4 on contact complies with IEC 61000-4-2

     

 

Non-dissipative shock wave:

 

  • 1 kV serial mode complies with IEC 60947-6-2
  • 2 kV common mode conforming and to IEC 60947-6-2

     

Control circuit voltage limits:

 

  • 20...26.5 V for AC circuit 24 V in operation
  • 14.5 V for AC circuit 24 V de-energizing

 

 

 

Typical current consumption:

 

  • 140 mA at 24 V AC I maximum during latching with LUB12
  • 220 mA at 24 V AC I maximum during closing with LUB32
  • 220 mA at 24 V AC I maximum during closing with LUB38
  • 70 mA at 24 V AC I rms fixed with LUB12
  • 90 mA at 24 V AC I rms fixed with LUB32
  • 90 mA at 24 V AC I rms fixed with LUB38

     

Heat dissipation:

 

 

  • 2 W per control circuit with LUB12
  • 3 W per control circuit with LUB32
  • 3 W per control circuit with LUB38


     

Operation time:

 

 

  • 35 ms opening with LUB12 per control circuit
  • 35 ms opening with LUB32 per control circuit
  • 35 ms opening with LUB38 per control circuit
  • 70 ms closing with LUB12 per control circuit
  • 70 ms closing with LUB32 for control circuit
  • 70 ms closing with LUB38 for control circuit

     

Standards:

 

 

  • EN 60947-6-2
  • IEC 60947-6-2
  • UL 60947-4-1, with phase spreader
  • CSA C22.2 No 60947-4-1, with phase spreader

     

 

Rated insulation voltage [Ui]:

 

 

  • 690 V complying with IEC 60947-6-2
  • 600 V in accordance with UL 60947-4-1
  • 600 V complying with CSA C22.2 No 60947-4-1

     

 

Safe circuit separation:

  • 400 V SELV between auxiliary and control circuits complies with IEC 60947-1
  • 400 V SELV between auxiliary or control circuit and main circuit complies with IEC 60947-1

     

 

Dimensions and weight:

  • Width 45 mm
  • Height 66 mm
  • Depth 60 mm
  • Weight: 135 grams

Data sheet

Type:
Control Unit
Voltage:
24V
Amps:
12A