Siemens 16A 1P+N 6kA 30mA Residual current operated Circuit Breaker A Curve C 2M 5SU13567KK16


SIE 5SU13567KK16 4001869306827

Siemens Residual current operated Circuit Breaker, combined protection against short circuits, overloads and current leakage. Ideal for domestic and industrial installations, with the following characteristics:

  • Rated current: 16 amps

  • Number of poles: 1P+N

  • Operating voltage: 230/240V AC

  • Interrupting capacity: 6 kA

  • Differential current: 30 mA

  • Tripping curve: C

  • Differential type: A

  • Number of modules: 2

  • Degree of protection: IP20

Do you have questions about this product or did you not find what you were looking for? Ask us!
Siemens 16A 1P+N 6kA 30mA Residual current operated Circuit Breaker A Curve C 2M 5SU13567KK16
€84.95
€84.95

€84.95
Tax included

€84.95

Buy it within 18h51m and receive it from Wednesday, 4 June
Two-year warranty
Easy return within 14 days

Comprehensive protection for your electrical system

The Siemens RCBO, integrates three basic protections:

  • Magnetic protection against short circuits, preventing fire and damage to the system
  • Thermal protection against overloads, preventing interruptions due to excessive loads
  • Differential protection (30mA) against current leakage, ensuring the safety of people

This combination makes it an essential device for electrical safety in homes, offices and small businesses.

Siemens RCBO: curve C and type A protection

C curve: ideal protection for mixed loads

Thanks to the C-curve tripping curve, the device is suitable for circuits with mixed loads, such as outlets and lighting, reducing the risks of unwanted interruptions.

Operation of the A-type earth leakage circuit breaker

Residual current circuit breaker type A tripping is assured for alternating sine differential currents and unidirectional pulsating differential currents applied suddenly or slowly increasing (IEC EN 61008-1).

Siemens RCBO: robustness, reliability and compliance

Robust and compact design

Designed for quick and easy DIN-rail installation, the device is 2 modules wide, taking up little space in the electrical panel. Constructed with halogen- and silicone-free materials, it provides enhanced environmental safety and durability.

Certified reliability and regulatory compliance

Made in accordance with CEI EN 61008-1 standards, it ensures safe and timely tripping of sine-sine alternating differential currents. It has a mechanical life of 10,000 switching cycles, ensuring reliable performance over time.

Features of the Siemens RCBO

Technical Data

Feature Value
Rated current 16A
Number of poles 1P+N
Voltage 230/240V AC
Differential current 30 mA
Breaking capacity 6 kA
Tripping curve C
Type of differential A
Number of modules 2


Installation and Protection

Feature Value
Degree of protection IP20
Maximum cable cross-section 0.75/35 mm²


Dimensions

Feature Value
Height 90 mm
Width 36 mm
Depth 77 mm
Recessed depth 70 mm

Data sheet

Modules:
2
Poles:
1P+N
Breaking capacity:
6KA
RCD Type:
A
Differential current :
0.03A
Amps:
16A
Circuit Protections:
RCBO