Siemens Residual Current Circuit Breaker 16A 1P+N 30MA F 10KA 2M 5SU13544KK16

Siemens Sentron residual current circuit breaker:
- 16A rated current
- Poles: 1P+N
- 30MA differential current
- F differential type
- Breaking capacity 10KA
- K super resistant
- 2 Modules

Tax included
The residual current circuit breaker is located next to the circuit breaker and integrates a magnetic protection to a thermal one, and in case of need it interrupts the electric current.
The residual current circuit breaker is, therefore, a system that combines the functions of the circuit breaker with magnetic and thermal features.
The residual current circuit breaker in the electrical system integrates three different protections:
- the magnetic one for short circuits that can endanger an entire building with the danger of fire;
- the thermal one for overloads in the power supply (e.g., more than one appliance in operation);
- the residual current circuit breaker's own residual current circuit breaker, which protects the subject from a power leakage
F-type residual current circuit breakers are specially developed for protection against indirect contact when using consumer appliances with single-phase inverters such as, for example, heat pumps and washing machines. In the event of an inverter ground fault they produce differential fault currents at varying frequencies, which AC and A-type earth leakage circuit breakers cannot detect.
Features:
- Super-strong product design K
- Number of poles 2
- Number of poles with protection 1
- Pole execution 1 pole+N
- Release characteristic class C
- Mechanical service life (switching cycles) typ. 10 000
- Overvoltage category III
- Pollution degree 2
Voltage:
- AC usage voltage type
- insulation voltage (Ui) rated value 264 V
- impulse withstand voltage rated value 4 000 V
- impulse withstand current for (8/20) µs 3 kA
- fault current per trip rated value 30 mA
- type of fault current F
Supply voltage:
- Supply voltage: with AC nominal value 230/240 V - for test device min. 195 V
- frequency of use 50/60 Hz
- frequency of supply voltage nominal value 50 Hz
General:
- IP20 degree of protection, for installation in distribution board, with conductors connected
- Power dissipation W max. 2.8 W
- cross section of connectable conductor rigid wire min. 0.75 mm² - max. 35 mm²
- section of conductor connectable multiwire min. 0.75 mm² - max. 35 mm²
- conductor cross section pluggable flexible wire with conductor end preparation min. 0.75 mm² - max. 25 mm²
- position of network cable optionally on top or bottom
- Dimensions: height 90 mm - width 36 mm - depth 77 mm - recessed depth 70 mm - number of modular units of width 2 - mounting position as desired
- net weight 271 g
- weight with packaging 283 g
Data sheet
- Modules: 2
- Poles: 1P+N
- Breaking capacity: 10KA
- RCD Type: F
- Differential current : 0.03A
- Amps: 16A
- Circuit Protections: RCBO