Rated current: 6 amps
-
Number of poles: 1P+N
-
Operating voltage: 230/240V AC
-
Interrupting capacity: 4.5 kA
-
Differential current: 30 mA
-
Intervention curve: C
-
Differential type: A
-
Number of modules: 2
-
Degree of protection: IP20
Siemens RCBO complete in one device
The Siemens residual current operated circuit breaker combines overload, short-circuit and leakage current protection in one compact module, ideal for residential and tertiary installations. Designed to the latest IEC EN 61008-1 standards, it is a reliable and compliant choice for the protection of people and property.
Integrated features
C curve: balanced protection for mixed loads.
Curve C allows a tripping time suitable for both resistive and inductive loads, reducing the risk of untimely trips.
Type A differential circuit breaker: Protects against alternating and pulsating differential currents, even with unidirectional components, for superior safety.
Triple protection:
-
Magnetic: against short circuits
-
Thermal: against overloads
-
Differential: against earth leakage (30 mA)
Ease of installation and reliability
The device occupies 2 DIN modules, facilitating integration into existing electrical panels. Due to its halogen-free material construction, it is also suitable in environments where low toxic smoke emission is required in case of fire. Mechanical durability guaranteed for more than 10,000 operation cycles.
Recommended applications
-
Civil electrical panels
-
Offices and commercial activities
-
Rooms with mixed loads (outlets + lighting)
-
Electrical installations where compact integrated protection is required
Siemens RCBO Technical Specifications
Technical Data
| Feature | Value |
|---|---|
| Rated current | 6A |
| Number of poles | 1P+N |
| Voltage | 230/240V AC |
| Differential current | 30 mA |
| Breaking capacity | 4.5 kA |
| Tripping curve | C |
| Type of differential | A |
| Number of modules | 2 |
Installation and Protection
| Feature | Value |
|---|---|
| Degree of protection | IP20 |
| Maximum cable cross-section | 0.75 / 35 mm² |
Dimensions
| Feature | Value |
|---|---|
| Height | 90 mm |
| Width | 36 mm |
| Depth | 77 mm |
| Recessed depth | 70 mm |
Data sheet
- Voltage: 230/240VAC
- Modules: 2
- Poles: 1P+N
- Curve: C
- Breaking capacity: 4.5KA
- RCD Type: A
- Differential current : 0.03A
- Amps: 6A
- Circuit Protections: RCBO