Abb residual current circuit breaker 16A 2P 30mA A 6KA DS202CRC16A30

Abb
ABB DS202CRC16A30 4022903033714

Abb DS202CR C16 A30 residual current circuit breaker:

 

  • 16A rated current
  • 2 Poles
  • Rated residual current 30mA (0.03)
  • Type A
  • Curve C
  • 2 Modules
  • Rated short-circuit power 6KA
  • Type AC input voltage
Do you have questions about this product or did you not find what you were looking for? Ask us!
Abb residual current circuit breaker 16A 2P 30mA A 6KA DS202CRC16A30
€131.76
€131.76

€131.76
Tax included
Calculate shipping cost

€131.76

Buy it within and receive it from Monday, 22 December
Two-year warranty
Easy return within 14 days

The residual current circuit breaker is located next to the circuit breaker and integrates a magnetic protection to a thermal one, and in case of need it interrupts the electric current.

 

The residual current circuit breaker is, therefore, a system that combines the functions of the circuit breaker with magnetic and thermal features.

 

The residual current circuit breaker in the electrical system integrates three different protections:

  • the magnetic one for short circuits that can endanger an entire building with the danger of fire;
  • the thermal one for overloads in the supply of electricity (e.g., more than one appliance in operation);
  • the differential one proper to the circuit breaker, which protects the subject from a power leakage

     

Curve C, trip threshold of 5 to 10 times In, for application of ohmic-inductive circuits with medium inrush currents. And widely used in domestic systems

 

The differential circuit breaker type A tripping is ensured for alternating sine differential currents and unidirectional pulsating differential currents applied suddenly or slowly increasing (IEC EN 61008-1).

 

The DS202CR series RCBO is a 2P device in two modules for protection of single-phase end-user circuits against overload and short-circuit currents. Protection against the effects of alternating and direct pulsating sinusoidal earth fault currents. Protection against indirect and additional contacts. Final protection against direct contacts.

 

Characteristics:

  • Reference standards: IEC/EN 61009-1 IEC/EN 61009-2-1
  • Rated operating voltage: according to IEC 60898-1 230 V
  • Rated insulation voltage (Ui): according to IEC/EN 60664-1 440 V
  • Impulse withstand voltage 4kV
  • Rated extreme short-circuit capacity 10kA
  • Maximum peak current: 0.25kA
  • Rated frequency (f): 50 Hz frequency
  • Power loss: 4.20 W
  • Energy limitation class: 3
  • Electrical resistance: 10000 operations
  • Mechanical resistance: 20000 operations
  • Fault indication: Blue flag on the window
  • Operating characteristic: Instantaneous
  • Overvoltage Category: III
  • Position of neutral terminals: Right Left
  • Tightening torque: 4 Nm
  • Connection capacity: Distribution rod 1010 mm² Flexible 1...25 mm² Rigid Solid 135 mm²
  • Nominal cross-section: 1 - Solid core 1 35 mm² 4 - Multi-Wired 1 25 mm²
  • Wire stripping length: 11 millimeters
  • Ambient temperature: In operation -25 55 °C
  • Degree of protection: IP20
  • Pollution degree: 3
  • Dimensions: Product width: 36mm width - 86mm height - 72mm depth
  • Product net weight: 0.220 kg
  • Built-in depth (t2): 72 millimeters.

Data sheet

Modules:
2
Poles:
2P
Curve:
C
Breaking capacity:
6KA
RCD Type:
AC
Differential current :
0.03A
Amps:
16A
Circuit Protections:
RCBO