Abb Circuit Breaker S204-63D 63A 4P 6KA D S552103

Abb
ABB S552103 4016779552103

The ABB S204-63D circuit breaker (S552103) 63A 4 poles 6kA curve D protects the system from overloads and short circuits, and is ideal for lines with high inrush currents such as motors and transformers. Compact 4 modules, ON/OFF indicator and high reliability of the S200 series.

  • Poles: 4P (4 protected poles)

  • Rated current (In): 63 A

  • Tripping curve: D (1029 × In) 

  • Rated short-circuit capacity: 6 kA (AC/DC), 400 V AC 6 kA

  • Icu (ultimate short-circuit capacity): 20 kA @230 V AC; 10 kA @400/440 V AC

  • Ics (service short-circuit capacity): 15 kA @230 V AC; 7.5 kA @400/440 V AC

  • Dielectric test voltage: 2 kV, 50/60 Hz 1 min

  • Energy limitation class: 3

  • Contact indication: Red ON / Green OFF

  • Electrical endurance: 10,000 cycles AC

  • Mechanical endurance: 20,000 cycles

  • Tightening torque: 2.8 Nm

  • Type of input voltage: AC/DC

  • Modules: 4

  • Dimensions (L×H×D): 70×88×69 mm

  • Weight: 0.48 kg.

Do you have questions about this product or did you not find what you were looking for? Ask us!
Abb Circuit Breaker S204-63D 63A 4P 6KA D S552103
€158.50
€158.50

€158.50
Tax included
Calculate shipping cost

€158.50

Buy it within and receive it from Tuesday, 3 February
Two-year warranty
Easy return within 14 days

ABB S204-63D: robust protection for loads with high inrush currents

The ABB S204-63D 63A is a circuit breaker from the System pro M compact S200 family, designed to protect electrical installations from overloads and short circuits with maximum service continuity. The 4-pole version is perfect for three-phase lines with neutral or for circuits where it is necessary to simultaneously interrupt all protected conductors, increasing the safety of the system and simplifying maintenance.

Curve D: the right choice for motors, transformers, and heavy lines

The curve D is designed for applications with high inrush currents: the magnetic trip threshold is between 10 and 29 times the rated current. In practice, this prevents unwanted tripping during the start-up of motors, the power supply of transformers, or loads with high inrush current (for example, some power supplies and industrial equipment). It is the ideal solution when a curve C circuit breaker would risk too frequent tripping during start-up phases.

Breaking capacity and performance: 6 kA for system protection

The device is rated with a short-circuit breaking capacity of 6 kA (AC/DC), suitable for distribution boards and installations where a reliable interruption level consistent with upstream protection is required. The energy limitation class 3 helps reduce the passing energy in case of a short circuit, containing thermal and dynamic stresses on cables and connected components: a tangible advantage for the longevity of the system.

Immediate status control: ON/OFF always visible

The status indication is clear and immediate: red = ON, green = OFF. In an electrical panel, this detail saves time during checks, interventions, and maintenance, especially when operating on multiple lines or in industrial environments where quick diagnosis is essential.

Compact and DIN rail mountable: perfect for modular panels

With a 4-module footprint and dimensions of 70×88×69 mm, the S204-63D easily integrates into standard modular panels. The terminal tightening torque of 2.8 N·m allows for stable and secure wiring, reducing the risk of loosening over time. The robustness is also supported by the endurance cycles: 10,000 electrical AC and 20,000 mechanical, for a long operational life even in challenging contexts.

AC/DC: flexibility of use

The AC/DC compatibility broadens the application scenarios, making the device suitable for both traditional alternating current circuits and certain direct current lines (always in compliance with the installation specifications and coordination with upstream protections).

TECHNICAL DATA
Dielectric test voltage 50/60 Hz – 1 min – 2 kV
Ultimate short-circuit breaking capacity (Icu) 230 V AC: 20 kA
400 V AC: 10 kA
440 V AC: 10 kA
Service short-circuit breaking capacity (Ics) 230 V AC: 15 kA
400 V AC: 7.5 kA
440 V AC: 7.5 kA
Power supply connection Arbitrary
Contact position indication Red ON / Green OFF
Energy limitation class 3
Electrical endurance 10,000 cycles AC
Mechanical endurance 20,000 cycles
Number of protected poles 4
Number of poles 4P
Tightening torque 2.8 N·m
Screw terminal type Failsafe Bi-directional Cylinder-lift Terminal
Actuator marking I / O
Actuator material Insulation group II, Black, Sealable
Recommended screwdriver Pozidriv 2
Available accessories Yes
CONNECTION CAPACITY
Busbar 10 / 10 mm²
Flexible conductor with ferrule 0.75 … 25 mm²
Flexible conductor 0.75 … 25 mm²
Rigid conductor 0.75 … 35 mm²
Stranded conductor 0.75 … 35 mm²
Stripping length 12.5 mm
Terminal type Screw terminals
ELECTRICAL CHARACTERISTICS
Tripping curve D
Operating voltage Max: 440 V AC
Min: 12 V AC / 12 V DC
Rated insulation voltage (Ui) 440 V (IEC/EN 60664-1)
Impulse withstand voltage (Uimp) 4 kV (standard)
5 kV at 2000 m
6.2 kV at sea level
Voltage type AC / DC
Rated current (In) 63 A
Rated short-circuit power 6 kA AC / DC
Conditional short-circuit current (Inc) 230 V: 20 kA
400 V: 20 kA
Rated frequency 50 / 60 Hz
Total power loss 19.2 W
Power loss per pole 4.8 W
Overvoltage category III

Data sheet

Voltage:
440V
Modules:
4
Poles:
4P
Curve:
D
Breaking capacity:
6KA
Amps:
63A
Circuit Protections: