Siemens Circuit Breaker 63A 3P 10KA curve D 3 modules 5SL43638
Siemens Circuit Breaker 5SL43638 3-pole 63A curve D, breaking capacity 10 kA. Ideal for circuits with high inrush currents such as motors, pumps, and transformers.
-
Siemens series 5SL circuit breaker
-
3 poles 3 DIN modules
-
Rated current: 63 A
-
Curve D: tripping threshold from 10 to 20× In
-
Breaking capacity: 10 kA
-
Insulation voltage: 440 V AC
-
Mechanical endurance: 10,000 cycles
-
Overvoltage category: III
-
Pollution degree: 2
-
Ideal for inductive loads with high starting currents.
Siemens Circuit Breaker Curve D: Reliable Protection for Motors and Transformers
The Siemens circuit breaker is designed to protect electrical circuits from overloads and short circuits, ensuring a quick and safe response. The curve D, designed for highly inductive loads, prevents unwanted trips in the presence of high inrush currents typical of:
-
Electric motors
-
Pumps and compressors
-
Transformers
-
Industrial plants and automation panels
The ability to withstand up to 1020 times the nominal current makes it perfect for professional and industrial applications.
Siemens Construction: Quality and Long Life
Designed to last over time, the device guarantees 10,000 mechanical operating cycles, ensuring reliability even in systems subject to frequent operations.
The DIN rail mounting and 3-module format allow for quick installation in domestic, commercial, and industrial electrical panels.
GENERAL TECHNICAL DATA
| Product Brand | SENTRON |
| Product Name | Circuit Breaker |
| Number of Poles | 3 |
| Pole Execution | 3 poles |
| Tripping Characteristic Class | D |
| Mechanical Lifespan | 10,000 cycles |
| Overvoltage Category | 3 |
| Pollution Degree | 2 |
VOLTAGE
| Type of Operating Voltage | AC |
| Type of Voltage | Use only in AC or DC. Mixed use is not allowed. |
| Insulation Voltage (Ui) | 440 V (multiphase AC) |
| Operating Current at 30°C | 63 A |
| Operating Current at 40°C | 60.45 A |
| Operating Current at 55°C | 56.41 A |
| Nominal AC Current | 63 A |
SUPPLY VOLTAGE
| AC Supply Voltage | 400 V |
| Frequency Range | 50 / 60 Hz |
| Max Operating Voltage AC | 440 V |
| Max Operating Voltage DC | 62.5 V (consider battery charge peak 72 V) |
PROTECTION CLASS
| IP Protection Rating | IP20 (with connected conductors) |
SWITCHING CAPACITY
| Breaking Capacity EN 60898 | 10 kA |
| Breaking Capacity IEC 60947-2 | 10 kA |
DISSIPATION
| Power Dissipation per Pole | 5 W |
SUITABILITY FOR USE
| Applications | Residential Building / Infrastructure |
DETAILS
| Accidental Contact Protection | Yes |
| Sectionable Neutral Conductor | No |
| Halogen-Free | Yes |
| Sealable Product | Yes |
| Silicone-free | Yes |
| Expansion with additional devices | Yes (flush mounting) |
Data sheet
- Modules: 3
- Poles: 3P
- Curve: D
- Breaking capacity: 10KA
- Amps: 63A
- Circuit Protections: Circuit breakers